Image Quality & Dose Management

DoseAware

Radiation Dose Tracker

Product number:

722360

Building a strong radiation safety culture starts with giving the medical staff real-time insight about their personal exposure. DoseAware is an active dosimetry system that provides real-time insights about radiation exposure, helping medical staff and physicians evaluate and directly adjust their behaviors.

Contact information

* This field is mandatory
*

Contact details

*
*
*

Company details

*
*
*
*
*

Business details

By specifying your reason for contact we will be able to provide you with a better service.
*
*
Features
Give staff real-time feedback || Dose Aware

Give staff real-time feedback

DoseAware measures and displays an individual’s exposure to radiation in real time. It gives staff immediate feedback on their level of scattered X-ray exposure and how their behavior affects it. The information provided by DoseAware helps staff track when and where dose was acquired, so they can take appropriate action during a procedure or work shift, if required.
Base Station shows the amount || Dose Aware

Base Station shows the amount

DoseAware is a flexible solution that can be used in any X-ray room for real-time feedback on scattered X-ray exposure. The PDM measures the X-ray dose received and is wirelessly connected to the Base Station, which can be mounted on an exam room monitor.
Personal Dose Meter (PDM) || Dose Aware

Personal Dose Meter (PDM)

Worn by the staff, this smart badge measures scatter radiation and transmits this information to the Base Stations (DoseAware) where it is displayed or radio hub (DoseAware Xtend). It makes DoseAware more flexible,since you can place its screen anywhere on the FlexVision XL display.
Live feedback to guide behavior* || Dose Aware

Live feedback to guide behavior*

During the procedure, the DoseAware Xtend live screen provides extra information to guide staff behavior. It shows the amount of real-time scattered X-ray dose per hour as a colored bar and the staff dose accumulated during the procedure in microsievert (μSv).
Dedicated room solution* || Dose Aware

Dedicated room solution*

DoseAware Xtend is a new dedicated solution for a treatment room that is integrated with the Allura FlexVision XL display and Allura X-ray systems. This integration allows DoseAware Xtend to provide more detailed feedback per procedure on scattered X-ray dose levels.
DoseView || Dose Aware

DoseView

This PC software package is included with DoseAware and DoseAware Xtend. It connects to a PDM via a cradle. DoseView enables you to view data on a PC, change names assigned to PDMs, or reset PDMs.
Dose Manager || Dose Aware

Dose Manager

Dose Manager is optional software that collects all data for reporting, exporting, and archiving. It can be connected to multiple Base Stations (DoseAware) or multiple radio hubs (DoseAware Xtend) via the hospital network.

Specifications

Personal Dose Meter
Personal Dose Meter
Weight
  • 30 grams (1.06 ounces)
Operational unit
  • 30 grams (1.06 ounces)
X-ray dose range
  • 1 μSv – 10 Sv
X-ray dose resolution
  • 1 μSv
X-ray dose uncertainty
  • 5% or 1 μSv
X-ray dose rate range and linearity
  • +/- 10% 40 μSv/h – 150 mSv/h
  • +/- 20% 150 mSv/h – 300 mSv/h
Energy dependency rays
  • N40-N120 (33 keV – 101 keV)
Average battery life
  • 3 – 5 years, depending on daily use
DoseAware Xtend Hub (to be mounted on ceiling)
DoseAware Xtend Hub (to be mounted on ceiling)
Dimensions
  • 13.5 x 18.5 x 3.5 cm (w x h x d) / 5.3 x 7.3 x 1.4 inch
Weight
  • 170 grams (6 ounces)
Display
  • via FlexVision XL
Resolution
  • 640 x 480 pixels
Storage
  • All X-ray dose-rate/sec and accumulated X-ray dose/hr that are received from PDMs in range.
  • For example: the memory size accommodates 250 PDMs with 50 hours X-ray dose rate history each.
Communication
  • Wireless radio communication with PDMs (868,3 918,3 927,9 MHz)
Ethernet
  • 10/100 Mbits/s port for the Dose Manager and connection to X-ray system.
DoseAware Xtend reporting
DoseAware Xtend reporting
Email reports
  • By week or by month, by PDM or by lab
Operator RDSR
  • Comprehensive Structured Report, up to 3 SCP can be configured as receivers.
Operator RDSR SOP class
  • UID 1.2.840.10008.5.1.4.1.1.88.33
DoseAware Base Station
DoseAware Base Station
Dimensions
  • 30 x 25 x 6 cm (w x h x d) / 11.8 x 9.8 x 2.4 inch
Weight
  • 1.45 kilograms (51.15 ounces)
Display
  • 10.4 inch touch screen
Resolution
  • 640 x 480 pixels
Storage
  • All X-ray dose-rate/sec and accumulated X-ray dose/hr that are received from PDMs in range.
  • For example: the memory size accommodates 250 PDMs with 50 hours X-ray dose rate history each.
Communication
  • Wireless radio communication with PDMs (868,3 918,3 927,9 MHz)
Ethernet
  • 10/100 Mbits/s port for the Dose Manager connection
Dose Manager (PC requirements)
Dose Manager (PC requirements)
Operation system
  • Windows XP, Vista or Windows 7
System memory
  • At least 2 GB
Hard disk
  • 40 GB with at least 15 GB available space - USB 2.0 port
DoseView (PC requirements)
DoseView (PC requirements)
Operation System
  • Windows XP, Vista or Windows 7
System memory
  • At least 1 GB - USB 2.0 port
  • * only for DoseAware Xtend