Reusable, adult SpO2 clip sensor
Pulse oximetry supplies
  • With the mid-point connector, you can switch among bedside, transport and mobile patient monitors without creating an unmanageable cable length.
  • Alternative product photograph
  • Standard product photograph

Reusable, adult SpO2 clip sensor

Pulse oximetry supplies
The reusable Philips M1196T adult clip sensor effectively measures pulse oximetry on adults and children weighing more than 40 kg (88 lbs). It is manufactured without latex. This sensor features a 90 cm (35.4 in) cable length and connects to 12-pin devices via M1900B adapter cable and connects to 8-pin devices via M1943A or M1943AL adapter cables and can be used with M4787A extension cable or validated 9-pin devices.

Features
Designed for FAST-SpO₂
Our pulse oximetry sensors are designed specifically for Philips proprietary FAST-SpO₂ (Fourier Artifact Suppression Technology) algorithm. Together, they reduce effects from patient movement, electronic interference, ambient light and low perfusion.
Durable and validated
All our SpO₂ sensors undergo demanding testing to make sure they meet Philips standards.
Comprehensive warranty
"Durable and cost-effective, the sensor is designed to withstand repeated use. It comes with a comprehensive warranty.* *Check with your local sales representative for the warranty details in your area."
Specifications
  • SpO2 Sensor
    Patient Application
    Child; Adult
    Application Site
    Finger
    Recommended Patient Weight
    >40 kg (>88 lb)
    Adapter Cable Compatibility
    M1943A; M1943AL
    Cable Length
    90 cm (35.4'')
  • Product details
    Product Category
    SpO2
    Use with Non-Philips Healthcare Equipment
    No
    Use with Philips Healthcare Equipment
    862108, 862231, 862439, 862474, 862478, 863051, 863053, 863054, 863063, 863064, 863065, 863066, 863068, 863069, 863071, 863072, 863073, 863074, 863077, 863080, 863081, 863085, 863086, 863087, 863088, 863264, 863265, 863266, 863276, 863278, M1020A, M1020B, M1350B, M1350C, M2600A, M2703A, M2704A, M2705A, M3000A, M3001A, M3002A, M3535A, M3536A, M3536M, M3926A, M3927A, M3928A, M3929A, M4735A, M8102A, M8105A, M8105AT, M8105AS
    Product Type
    Sensor
    Single-Patient Use OR Multi-Patient Use
    Multi-Patient Use
    CE Certified
    Yes
    Package Weight
    .240
    Not manufactured with natural rubber latex
    Yes
    Packaging Unit
    1 sensor
    Minimum Shelf Life
    None
    Sterile OR Non-Sterile
    Non-Sterile
    Use with Other Supplies
    M1900B, M1943A, M1943AL, M4787A

Documentation

Studies of new generation Pulse Oximetry technologies
PDF|240.80 KB
Product Brochure
PDF|1.86 MB
Reusable sensors that last
PDF|831.63 KB
SpO₂ sensors that last
PDF|649.95 KB


Related products

  • Multi-patient, 8-pin to 9-pin D-sub adapter cable, 1.1 m (3.6 ft) Pulse oximetry supplies
    Designed for use with Philips SpO₂ monitors and sensors, the M1943A 8-pin adapter cable is 1.1 m (3.6 ft) in length and features a D-sub connector. It adapts 9-pin sensors to 8-pin sockets. It can be used with these sensors: M1131A, M1132A, M1133A, M1134A, M1140A, M1191T, M1192T, M1193T and M1196T.
  • Reusable adult SpO₂ glove sensor with mid-point connector Pulse oximetry supplies
    The Philips M1191T SpO₂ glove sensor features a mid-point connector for efficient transfer from a bedside to a transport or mobile patient monitor. It is designed for use on the fingers of adults greater than 50 kg (110 lbs). This durable, comfortable sensor is manufactured without latex and supports cost-effective oxygen saturation measurement.
  • Reusable, adult SpO₂ clip sensor Pulse oximetry supplies
    The reusable Philips M1196A adult clip sensor effectively measures pulse oximetry in adults and children weighing more than 40 kg (88 lbs). It features a 3.0m (9.8 ft) cable length to accommodate varied monitor placement. It is manufactured without latex.
  • Multi-patient, 8-pin to 9-pin D-sub adapter cable, 3 m (9.8 ft) Pulse oximetry supplies
    Designed for use with Philips SpO₂ monitors and sensors, the M1943AL adapter cable is 3 m (9.8 ft) in length and features a D-sub connector. It adapts 9-pin sensors to 8-pin sockets. It can be used with these sensors: M1131A, M1132A, M1133A, M1134A, M1140A, M1191T, M1192T, M1193T and M1196T.
Disclaimer
Product may not be available in all geographies, please check with your Philips representative for complete portfolio availability.